Pass boxserve as critical logistics channels between clean and general areas in dairy production, with their hygiene management directly impacting product safety. Below are key standards based on industry practices:
1. Material Selection
· Main Body: Constructed with food-grade stainless steel (e.g., 304 or higher) for non-toxic, anti-corrosive, and easy-to-clean properties, minimizing contamination risks from material degradation.
· Sealing Materials: Use food-grade rubber/silicone seals that are odorless, anti-aging, and chemically stable to ensure airtightness and prevent chemical reactions with dairy products.
2. Structural Design
· Smooth Interior: Simple, seamless surfaces with rounded corners (R≥5mm) to eliminate hygienic dead zones and facilitate cleaning, reducing microbial adhesion.
· Airtightness & Interlock: Equipped with sealed doors/air curtains and interlocking systems to prevent cross-contamination by ensuring only one door opens at a time, maintaining pressure stability between zones.
· Optimal Size: Designed based on the largest item dimensions to avoid redundant space, balancing functionality and energy efficiency.
3. Cleaning & Disinfection
· Daily Cleaning: Wipe interiors with neutral food-grade detergents after production and before/after each use to remove residues and prevent cross-contamination.
· Periodic Disinfection: Weekly deep disinfection using UV light (≥30 minutes) or food-safe disinfectants (e.g., quaternary ammonium, peracetic acid), following a "from inside-out, top-down" order. Validate disinfectant compatibility with materials.
· Emergency Treatment: Immediate disinfection (including ozone if needed) after transferring high-risk items (e.g., raw material packaging) to control microbial risks promptly.
4. Air Purification
· HEPA Filtration: Install HEPA filters (≥99.97%@0.3μm) in Class A/B clean zones, ensuring airtight installation to prevent unfiltered bypass in critical areas.
· Pressure Control: Maintain directional pressure (positive/negative) via sensors and valves to ensure airflow from clean to less clean areas, with daily pressure monitoring and calibration.
· Maintenance: Replace HEPA filters every 1–2 years or when resistance increases by 50%, followed by integrity testing to ensure efficiency.
5. Microbial Monitoring
· Routine Testing: Quarterly sampling of surfaces, air, and contact points (e.g., door handles) for microbial load (e.g., sedimentation bacteria ≤5CFU/dish・30min) per GB 4789.2 standards.
· Non-Compliance Response: Immediate enhanced disinfection and source tracing (e.g., seal failure, filter leaks) if results exceed limits, re-approving use only after passing retests.
· Preventive Measures: Prohibit storing non-production items, check packaging integrity before transfer, and train operators to reduce human-induced contamination.
By integrating material selection, structural design, cleaning, air purification, and microbial control, Pass box maintain controlled cleanliness, ensuring a safe environment for dairy production.